BMP085/BMP18x digital pressure sensors
Required properties:
- compatible: bosch,bmp085
Optional properties:
- chip-id: configurable chip id for non-default chip revisions
- temp-measurement-period: temperature measurement period (milliseconds)
- default-oversampling: default oversampling value to be used at startup,
value range is 0-3 with rising sensitivity.
Example:
pressure@77 {
compatible = "bosch,bmp085";
reg = <0x77>;
chip-id = <10>;
temp-measurement-period = <100>;
default-oversampling = <2>;
};