TI SOC EHRPWM based PWM controller Required properties: - compatible: Must be "ti,<soc>-ehrpwm". for am33xx - compatible = "ti,am33xx-ehrpwm"; for da850 - compatible = "ti,da850-ehrpwm", "ti,am33xx-ehrpwm"; - #pwm-cells: should be 3. See pwm.txt in this directory for a description of the cells format. The only third cell flag supported by this binding is PWM_POLARITY_INVERTED. - reg: physical base address and size of the registers map. Optional properties: - ti,hwmods: Name of the hwmod associated to the EHRPWM: "ehrpwm<x>", <x> being the 0-based instance number from the HW spec Example: ehrpwm0: ehrpwm@0 { /* EHRPWM on am33xx */ compatible = "ti,am33xx-ehrpwm"; #pwm-cells = <3>; reg = <0x48300200 0x100>; ti,hwmods = "ehrpwm0"; }; ehrpwm0: ehrpwm@0 { /* EHRPWM on da850 */ compatible = "ti,da850-ehrpwm", "ti,am33xx-ehrpwm"; #pwm-cells = <3>; reg = <0x300000 0x2000>; };