Adaptive Body Bias(ABB) SoC internal LDO regulator for Texas Instruments SoCs

Required Properties:
- compatible: Should be one of:
  - "ti,abb-v1" for older SoCs like OMAP3
  - "ti,abb-v2" for newer SoCs like OMAP4, OMAP5
  - "ti,abb-v3" for a generic definition where setup and control registers are
     provided (example: DRA7)
- reg: Address and length of the register set for the device. It contains
  the information of registers in the same order as described by reg-names
- reg-names: Should contain the reg names
  - "base-address"	- contains base address of ABB module (ti,abb-v1,ti,abb-v2)
  - "control-address"	- contains control register address of ABB module (ti,abb-v3)
  - "setup-address"	- contains setup register address of ABB module (ti,abb-v3)
  - "int-address"	- contains address of interrupt register for ABB module
  (also see Optional properties)
- #address-cell: should be 0
- #size-cell: should be 0
- clocks: should point to the clock node used by ABB module
- ti,settling-time: Settling time in uSecs from SoC documentation for ABB module
	to settle down(target time for SR2_WTCNT_VALUE).
- ti,clock-cycles: SoC specific data about count of system ti,clock-cycles used for
	computing settling time from SoC Documentation for ABB module(clock
	cycles for SR2_WTCNT_VALUE).
- ti,tranxdone-status-mask: Mask to the int-register to write-to-clear mask
	indicating LDO tranxdone (operation complete).
- ti,abb_info: An array of 6-tuples u32 items providing information about ABB
	configuration needed per operational voltage of the device.
	Each item consists of the following in the same order:
	volt: voltage in uV - Only used to index ABB information.
	ABB mode: one of the following:
		0-bypass
		1-Forward Body Bias(FBB)
		3-Reverse Body Bias(RBB)
	efuse:	(see Optional properties)
	RBB enable efuse Mask:	(See Optional properties)
	FBB enable efuse Mask:	(See Optional properties)
	Vset value efuse Mask:	(See Optional properties)

	NOTE: If more than 1 entry is present, then regulator is setup to change
	      voltage, allowing for various modes to be selected indexed off
	      the regulator. Further, ABB LDOs are considered always-on by
	      default.

Optional Properties:
- reg-names: In addition to the required properties, the following are optional
  - "efuse-address"	- Contains efuse base address used to pick up ABB info.
  - "ldo-address"	- Contains address of ABB LDO overide register address.
	"efuse-address" is required for this.
- ti,ldovbb-vset-mask	- Required if ldo-address is set, mask for LDO override
	register to provide override vset value.
- ti,ldovbb-override-mask - Required if ldo-address is set, mask for LDO
	override register to enable override vset value.
- ti,abb_opp_sel: Addendum to the description in required properties
	efuse: Mandatory if 'efuse-address' register is defined. Provides offset
	       from efuse-address to pick up ABB characteristics. Set to 0 if
	       'efuse-address' is not defined.
	RBB enable efuse Mask:	Optional if 'efuse-address' register is defined.
		'ABB mode' is force set to RBB mode if value at "efuse-address"
		+ efuse maps to RBB mask. Set to 0 to ignore this.
	FBB enable efuse Mask:	Optional if 'efuse-address' register is defined.
		'ABB mode' is force set to FBB mode if value at "efuse-address"
		+ efuse maps to FBB mask (valid only if RBB mask does not match)
		Set to 0 to ignore this.
	Vset value efuse Mask:	Mandatory if ldo-address is set. Picks up from
		efuse the value to set in 'ti,ldovbb-vset-mask' at ldo-address.

Example #1: Simplest configuration (no efuse data, hard coded ABB table):
abb_x: regulator-abb-x {
	compatible = "ti,abb-v1";
	regulator-name = "abb_x";
	#address-cell = <0>;
	#size-cells = <0>;
	reg = <0x483072f0 0x8>, <0x48306818 0x4>;
	reg-names = "base-address", "int-address";
	ti,tranxdone-status-mask = <0x4000000>;
	clocks = <&sysclk>;
	ti,settling-time = <30>;
	ti,clock-cycles = <8>;
	ti,abb_info = <
	/* uV		ABB	efuse	rbb_m	fbb_m	vset_m */
	1012500		0	0	0	0	0 /* Bypass */
	1200000		3	0	0	0	0 /* RBB mandatory */
	1320000		1	0	0	0	0 /* FBB mandatory */
	>;
};

Example #2: Efuse bits contain ABB mode setting (no LDO override capability)
abb_y: regulator-abb-y {
	compatible = "ti,abb-v2";
	regulator-name = "abb_y";
	#address-cell = <0>;
	#size-cells = <0>;
	reg = <0x4a307bd0 0x8>, <0x4a306014 0x4>, <0x4A002268 0x8>;
	reg-names = "base-address", "int-address", "efuse-address";
	ti,tranxdone-status-mask = <0x4000000>;
	clocks = <&sysclk>;
	ti,settling-time = <50>;
	ti,clock-cycles = <16>;
	ti,abb_info = <
	/* uV		ABB	efuse	rbb_m	fbb_m	vset_m */
	975000		0	0	0	0	0 /* Bypass */
	1012500		0	0	0x40000	0	0 /* RBB optional */
	1200000		0	0x4	0	0x40000	0 /* FBB optional */
	1320000		1	0	0	0	0 /* FBB mandatory */
	>;
};

Example #3: Efuse bits contain ABB mode setting and LDO override capability
abb_z: regulator-abb-z {
	compatible = "ti,abb-v2";
	regulator-name = "abb_z";
	#address-cell = <0>;
	#size-cells = <0>;
	reg = <0x4ae07ce4 0x8>, <0x4ae06010 0x4>,
	      <0x4a002194 0x8>, <0x4ae0C314 0x4>;
	reg-names = "base-address", "int-address",
		    "efuse-address", "ldo-address";
	ti,tranxdone-status-mask = <0x8000000>;
	/* LDOVBBMM_MUX_CTRL */
	ti,ldovbb-override-mask = <0x400>;
	/* LDOVBBMM_VSET_OUT */
	ti,ldovbb-vset-mask = <0x1F>;
	clocks = <&sysclk>;
	ti,settling-time = <50>;
	ti,clock-cycles = <16>;
	ti,abb_info = <
	/* uV	ABB	efuse	rbb_m	fbb_m	vset_m */
	975000	0	0	0	0	0	/* Bypass */
	1200000	0	0x4	0	0x40000	0x1f00	/* FBB optional, vset */
	>;
};